EPA describes short-term radon tests as the quickest way to test and long-term tests as the better guide to your year-round average. The two are often used together. This page compares them side by side and sets out the EPA steps for follow-up testing.
The two types of radon test
EPA describes two general ways to test for radon. Short-term tests stay in your home from two to 90 days, depending on the device. Long-term tests stay in your home for more than 90 days. Because radon levels vary from day to day and season to season, a short-term test is less likely than a long-term test to tell you your year-round average.
Short-term and long-term radon tests compared (EPA) | Short-term test | Long-term test |
|---|
| How long | 2 days to 90 days, depending on the device | More than 90 days |
| Common devices | Charcoal canisters, alpha track, electret ion chamber, continuous monitors, charcoal liquid scintillation | Alpha track and electret ion chamber detectors |
| Speed | The quickest way to test | Takes longer |
| Year-round average | Less likely to show it, because radon varies from day to day and season to season | More likely to show your home's year-round average |
| Minimum time | All radon tests should run at least 48 hours; some devices need longer | Well beyond 48 hours by definition |
| Closed-house conditions | Keep windows and outside doors closed as much as possible; for 2 to 3 day tests, close them at least 12 hours before the test begins | Follow the instructions that come with the kit |
| Best used for | A first screening test, or a quick follow-up test | A fuller picture of the year-round level, when time allows |
Tests are also grouped as passive devices, which need no power and are sent to a lab, and active devices, which need power and record readings over time. Qualified radon testers may use any of these devices. If you hire a professional, ask them what protocol they follow. AARST publishes ANSI/AARST MAH-2023, a standard for measuring radon in homes.
EPA's follow-up testing steps
- Step 1. Take a short-term test. If the result is 4 pCi/L or higher, take a follow-up test to be sure.
- Step 2. Follow up with either a long-term test or a second short-term test. For a better understanding of your year-round average, take a long-term test. If you need results quickly, take a second short-term test. If your first short-term result is more than twice EPA's 4 pCi/L action level, take a second short-term test immediately.
- Step 3. After a long-term follow-up, fix your home if the result is 4 pCi/L or more. After a second short-term test, consider fixing if the average of the two tests is 4 pCi/L or higher.
EPA also says to consider fixing between 2 and 4 pCi/L. The WHO reference level is 2.7 pCi/L (100 Bq/m3).
Closed-house conditions
EPA's guidance for short-term tests is to close windows and outside doors and keep them closed as much as possible during the test. Heating and air conditioning fans that re-circulate air may be operated. Fans that are part of a radon reduction system, and small exhaust fans that run only for short periods, may run too. For a 2 to 3 day test, close windows and outside doors at least 12 hours before the test begins.
How to choose
- Need a result soon? Start with a short-term test. EPA says it is the quickest way to test.
- Want a view of the whole year? A long-term test is more likely to show your year-round average.
- First result at 4 pCi/L or higher? Follow up. If the first result is more than twice the action level, EPA says take a second short-term test immediately.
- In a home sale? Follow the real estate guidance in EPA's Home Buyer's and Seller's Guide.
For help choosing a kit, see how to choose a radon test kit. For testing basics, see radon testing.
Frequently Asked Questions
Which is better, a short-term or a long-term radon test?
Neither is better in every case. A short-term test is the quickest way to test. A long-term test is more likely to show your year-round average. EPA says to take a short-term test first and then follow up with either a long-term test or a second short-term test.
Can I make a decision with only a short-term test?
EPA says a short-term test followed by a second short-term test can be used to decide whether to fix your home. If the average is close to 4 pCi/L, you can be less certain whether your year-round average is above or below that level. EPA gives an example: if the average of two short-term tests is 4.1 pCi/L, there is about a 50% chance that the year-round average is somewhat below 4.
What are closed-house conditions?
They mean keeping windows and outside doors closed as much as possible during the test. For a short-term test lasting only 2 or 3 days, close them at least 12 hours before beginning too. EPA says not to run fans or machines that bring in air from outside, and not to conduct 2 to 3 day tests during unusually severe storms or periods of unusually high winds.
How long is a long-term test?
A long-term test stays in your home for more than 90 days, according to EPA. See the long-term radon test kits for kit options.
Which test should I use if I am buying or selling a home?
EPA's Home Buyer's and Seller's Guide describes short-term test options that are acceptable in a real estate transaction when you need results quickly. The Citizen's Guide adds that the result of two short-term tests can be used in a real estate transaction. See radon testing when buying a home for details.
Sources
The durations, steps and conditions on this page come from EPA's guides. The AARST standard is named for context only.
- EPA, A Citizen's Guide to Radon (PDF): EPA testing steps, test placement, closed-house conditions, and what test results mean.
- EPA, Home Buyer's and Seller's Guide to Radon (PDF, March 2024 revision): testing and fixing radon during a home sale.
- EPA, Consumer's Guide to Radon Reduction (PDF): how radon reduction systems work, hiring a contractor, and maintaining a system.
- EPA, What is EPA's Action Level for Radon and What Does it Mean?: the 4 pCi/L action level, the 2 to 4 pCi/L range, and average indoor radon.
- EPA, Does the 2009 WHO recommendation affect EPA's action level?: how EPA describes the WHO reference level of 2.7 pCi/L.
- AARST, ANSI/AARST MAH-2023: Protocol for Conducting Measurements of Radon and Radon Decay Products in Homes: the standard's published scope: procedures and minimum requirements for measuring radon in single-family homes.
- EPA, Find a Radon Test Kit or Measurement and Mitigation Professional: where to get test kits and how to find qualified radon service providers.