Radon.org logo

How to Test for Radon at Home: Step-by-Step

Ten steps, from choosing a kit to reading your result, based on EPA guidance.

Last reviewed:

Quick answer

To test for radon, put a test kit on the lowest lived-in level of your home, in a regularly used room but not a kitchen or bathroom, and follow the kit instructions. EPA recommends starting with a short-term test and taking a follow-up test if the result is 4 pCi/L or higher.

Source: EPA, A Citizen’s Guide to Radon (2025). Last reviewed:

As an Amazon Associate we earn from qualifying purchases. Affiliate disclosure

Testing for radon is a few minutes of work. The steps below follow EPA's guidance for a home test kit, from where to place it to what to do with your result.

Before you start

EPA and the Surgeon General recommend testing all homes below the third floor. Testing is the only way to know your home's radon level. If you are new to radon, read why test for radon first.

Step-by-step: how to test your home

  1. Choose short-term or long-term. A short-term test is the quickest. A long-term test is more likely to show your year-round average. EPA recommends starting with a short-term test and following up as needed. See short-term vs long-term radon tests.
  2. Get a qualified test kit. Kits are sold in hardware stores and online. Your state radon program and the National Radon Program Services at Kansas State University can point you to qualified kits. Make sure the device comes from a qualified laboratory. See how to choose a radon test kit.
  3. Pick the right spot. Use the lowest lived-in level of the home. EPA gives a basement as an example if it is frequently used, otherwise the first floor. Choose a room used regularly, such as a living room, playroom, den or bedroom, but not a kitchen or bathroom.
  4. Place the kit well. Put it at least 20 inches above the floor in a place where it will not be disturbed, away from drafts, high heat, high humidity and exterior walls.
  5. Set closed-house conditions. For a short-term test, close windows and outside doors and keep them closed as much as possible. For a 2 to 3 day test, close them at least 12 hours before beginning. Do not run fans or machines that bring in outside air. Avoid 2 to 3 day tests during unusually severe storms or very high winds.
  6. Start the test and note the time. Follow the instructions in the box and write down the start date and time and the end date and time.
  7. Leave it in place for the full time. Leave the kit for as long as the package says. EPA says all radon tests need at least 48 hours.
  8. Reseal and mail it right away. When the test period ends, reseal the package and send it to the lab named on the package right away. EPA says you should receive your results within a few weeks, and the exact time varies by lab.
  9. Read your result. Results are given in picocuries per liter (pCi/L). EPA says to fix your home at 4 pCi/L or higher, and to consider fixing between 2 and 4. See the radon levels chart.
  10. Follow up if needed. If a short-term result is 4 pCi/L or higher, EPA says to take a follow-up test. If it is more than twice 4 pCi/L, take a second short-term test immediately. See what to do if your radon test is high.

Recommended test kit or monitor

First Alert Radon Gas Test Kit RD1, radon test kit product photo from the Amazon listing

First Alert Radon Gas Test Kit RD1

Best for: Simple short-term mail-in test

Manufacturer-stated: test materials and lab fees included (excluding NJ state fees)

Check price on Amazon
RadonAway Complete Radon Test Kit, radon test kit product photo from the Amazon listing

RadonAway Complete Radon Test Kit

Best for: Lab fee included

Manufacturer-stated: analysis by a NELAP-approved lab included

Check price on Amazon
Ecosense EcoBlu EB100, radon monitor product photo from the Amazon listing

Ecosense EcoBlu EB100

Best for: Plug-in monitor with on-screen display

Manufacturer-stated: no smartphone, Wi-Fi or battery needed

Check price on Amazon

Compare detectors · Radon test kits

What your result means

EPA recommends fixing a home at 4.0 pCi/L or higher and says to consider fixing between 2 and 4 pCi/L. The WHO reference level is 2.7 pCi/L (100 Bq/m3). The average indoor level is estimated at about 1.3 pCi/L and about 0.4 pCi/L is normally found outdoors. EPA also says no level of radon is known to be safe, so lower is better.

If your result is 4.0 pCi/L or higher, see what to do if your radon test is high. For fixing a home, see radon mitigation.

If you would rather hire a tester

EPA says you can hire a qualified radon tester. Check with your state radon office for a list of qualified testers. AARST publishes ANSI/AARST MAH-2023, which sets out procedures and minimum requirements for measuring radon in homes. Professionals may work to standards like this one.

Frequently Asked Questions

Where should I put a radon test kit?

EPA says to place the kit in the lowest lived-in level of the home, in a room used regularly but not a kitchen or bathroom. Put it at least 20 inches above the floor, away from drafts, high heat, high humidity and exterior walls.

How long should I leave the test in place?

Leave the kit in place for as long as the package says. EPA says all radon tests should run for a minimum of 48 hours, and some devices need longer. See how long a radon test takes.

Do I need to keep windows closed during a radon test?

For a short-term test, yes. EPA says to close windows and outside doors and keep them closed as much as possible. For a 2 to 3 day test, close them at least 12 hours before beginning the test, too.

What do I do if my result is 4.0 pCi/L or higher?

Follow up with another test, then consider hiring a qualified mitigator. EPA says to take a follow-up test if a short-term result is 4 pCi/L or higher, and to fix your home if a long-term result is 4 pCi/L or more. See what to do if your radon test is high.

Do I need a professional to test for radon?

No. EPA says you can test yourself with a kit or hire a qualified tester. A qualified tester can also explain a continuous monitor's report to you. Use a kit from a qualified laboratory and follow its instructions.

Sources

Every placement, timing and result threshold in the steps comes from these sources.